Where to restart the PV PID module

To restart a PV PID module, you need to turn off the AC and DC circuit breakers, set the module type via jumper terminals, and then power it back on following the manufacturer's instructions.Step...

Where to restart the PV PID module

To restart a PV PID module, you need to turn off the AC and DC circuit breakers, set the module type via jumper terminals, and then power it back on following the manufacturer's instructions.

Step-by-Step Restart Procedure

  1. Power Down the Module
    • For SUN2000 inverters, turn off the AC side circuit breaker of the PID module.
    • For SUN8000 inverters, turn off both DC and AC side circuit breakers to ensure complete isolation before maintenance .
  2. Access the Jumper Terminals
    • Loosen the two captive screws on the PID module and remove the front panel to access the jumper terminals .
    • The jumper determines the PV module type (P-type or N-type) and must match the modules in your array.
  3. Set the PV Module Type
    • For P-type PV modules, insert the jumper into the J61 port.
    • For N-type PV modules, insert the jumper into the J62 port .
    • Ensure the jumper is securely seated to avoid incorrect PID operation.
  4. Reinstall the Front Panel
    • After setting the jumper, replace the front panel and tighten the screws to secure it.
  5. Power Up the Module
    • Turn on the DC and AC circuit breakers in the correct sequence according to your inverter type.
    • The PID module will resume operation and begin mitigating PID effects, often using night mode or automatic mode to reverse degradation over time .

Additional Considerations

  • Grounding: Ensure the negative DC pole is properly grounded if your inverter supports this mode, as it helps reduce PID risk .
  • Monitoring: Recovery from PID may take several weeks to months, depending on module type, degradation depth, and environmental conditions .
  • Maintenance: Regularly check jumper settings and module performance to ensure PID mitigation is effective. Following these steps ensures that the PV PID module is correctly restarted and configured to continue protecting your solar array from potential induced degradation.
Factory
Feb 19, 2026

PV inverters for preventing the PID effect | Kaco New Energy

The PID effect will be strongly increased, depending on the quality of your PV panels, the length of the module strings, high ambient

Factory
Jul 13, 2026

The Negative Impacts of Potential Induced Degradation (PID) and

The SPOT contains a set galvanically isolated DC -DC converters. The galvanic isolation feature allows the SPOT to reverse the

Factory
Oct 26, 2025

All about PID – testing and avoidance in the field

Potential-induced degradation (PID) in PV modules is activated by the stress of system voltage and the resulting small but

Factory
Jan 09, 2026

Potential Induced Degradation (PID): how to reverse or

Discover what is Potential Induced Degradation (PID), how solar PID is detected, and equipment to reverse or prevent this regularly

Factory
May 14, 2026

Setting the PV Module Type

Insert the jumper in the corresponding port based on the type of PV modules used in a power station. If a power station uses PV

Factory
Nov 15, 2025

PID – Potenzial-induzierte Degradation

Potenzial-induzierte Degradation (PID) bezieht sich auf eine Phänomen, bei dem Solar-Module an Leistungsfähigkeit verlieren und

Factory
Sep 07, 2025

Potential Induced Degradation (PID)

The phenomenon described here occurs most commonly in the PV module that is closest to the negative pole — the "lowest" PV

Factory
Mar 01, 2026

Potential-induced degradation

Potential-induced degradation (PID) is a potential-induced performance degradation in crystalline photovoltaic modules, caused by

Factory
Aug 05, 2025

Working Principle

Working Principle The PID module is a component of a SUN2000 or SUN8000 PV array with the power of less than or equal to 2

Power Grid Optical Insights

Need Reliable Optical Solutions for Power Grids?

Contact us for OPGW, ADSS, hardware, and communication systems – we respond within 24 hours.